Fire resistance solutions, F62 Paint - Side cement floor protection with plaster

If you have used this product in your project. Click here to publish you project on SYNCRONIA!

Description

Fire safety retrofitting of hollow-core concrete and clay (laterocemento) slabs represents a fundamental technical challenge in building renovation. When the substrate already features a layer of cement plaster, it is possible to intervene with low-thickness systems that preserve aesthetics while ensuring high performance.

...Read more

Fire safety retrofitting of hollow-core concrete and clay (laterocemento) slabs represents a fundamental technical challenge in building renovation. When the substrate already features a layer of cement plaster, it is possible to intervene with low-thickness systems that preserve aesthetics while ensuring high performance.


The system proposed by Elmo utilizes F62 PAINT intumescent coating, applied with an optimized consumption of 0.9 kg/m². This solution has been tested according to EN 1365-2 on slabs with a thickness of 16+4 cm and 10 mm of plaster, achieving a REI 180 classification.


Integration of Systems and Electrical Boxes


A key strength of this certification (Report I.G. 347890/3892FR) is the ability to manage the presence of electrical boxes and corrugated pipes applied to the soffit. This allows for building code compliance without dismantling existing systems, ensuring continuity of passive fire protection.


Download


Download free technical design files from this product page. Specifically, you can download: BIM .rvt files, detailed technical data sheets, catalogs, and specifications dedicated to F62 Paint for the protection of hollow-core concrete and clay slabs with plaster.

Read less

test